Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Sci Rep ; 14(1): 8718, 2024 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622275

RESUMO

Chronic Obstructive Pulmonary Disease (COPD) is characterized by progressive and irreversible airflow limitation, with individual body composition influencing disease severity. Severe emphysema worsens symptoms through hyperinflation, which can be relieved by bronchoscopic lung volume reduction (BLVR). To investigate how body composition, assessed through CT scans, impacts outcomes in emphysema patients undergoing BLVR. Fully automated CT-based body composition analysis (BCA) was performed in patients with end-stage emphysema receiving BLVR with valves. Post-interventional muscle and adipose tissues were quantified, body size-adjusted, and compared to baseline parameters. Between January 2015 and December 2022, 300 patients with severe emphysema underwent endobronchial valve treatment. Significant improvements were seen in outcome parameters, which were defined as changes in pulmonary function, physical performance, and quality of life (QoL) post-treatment. Muscle volume remained stable (1.632 vs. 1.635 for muscle bone adjusted ratio (BAR) at baseline and after 6 months respectively), while bone adjusted adipose tissue volumes, especially total and pericardial adipose tissue, showed significant increase (2.86 vs. 3.00 and 0.16 vs. 0.17, respectively). Moderate to strong correlations between bone adjusted muscle volume and weaker correlations between adipose tissue volumes and outcome parameters (pulmonary function, QoL and physical performance) were observed. Particularly after 6-month, bone adjusted muscle volume changes positively corresponded to improved outcomes (ΔForced expiratory volume in 1 s [FEV1], r = 0.440; ΔInspiratory vital capacity [IVC], r = 0.397; Δ6Minute walking distance [6MWD], r = 0.509 and ΔCOPD assessment test [CAT], r = -0.324; all p < 0.001). Group stratification by bone adjusted muscle volume changes revealed that groups with substantial muscle gain experienced a greater clinical benefit in pulmonary function improvements, QoL and physical performance (ΔFEV1%, 5.5 vs. 39.5; ΔIVC%, 4.3 vs. 28.4; Δ6MWDm, 14 vs. 110; ΔCATpts, -2 vs. -3.5 for groups with ΔMuscle, BAR% < -10 vs. > 10, respectively). BCA results among patients divided by the minimal clinically important difference for forced expiratory volume of the first second (FEV1) showed significant differences in bone-adjusted muscle and intramuscular adipose tissue (IMAT) volumes and their respective changes after 6 months (ΔMuscle, BAR% -5 vs. 3.4 and ΔIMAT, BAR% -0.62 vs. 0.60 for groups with ΔFEV1 ≤ 100 mL vs > 100 mL). Altered body composition, especially increased muscle volume, is associated with functional improvements in BLVR-treated patients.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Pneumonectomia/métodos , Qualidade de Vida , Broncoscopia/métodos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Enfisema Pulmonar/etiologia , Enfisema/etiologia , Volume Expiratório Forçado/fisiologia , Composição Corporal , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
J Nucl Med ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637142

RESUMO

Para-aminohippurate, also known as p-aminohippuric acid (PAH), is used clinically to measure effective renal plasma flow. Preclinically, it was shown to reduce 177Lu-DOTATOC uptake in the kidneys while improving bioavailability compared with amino acid (AA) coinfusion. We report the safety and efficacy of PAH coinfusion during peptide receptor radiotherapy in patients with neuroendocrine tumors. Methods: Twelve patients with metastatic or unresectable gastroenteropancreatic neuroendocrine tumors received 177Lu-DOTATOC in 33 treatment cycles. Either 8 g of PAH or a mixture of 25 g of arginine and 25 g of lysine were coinfused. Safety was assessed by monitoring laboratory data, including hematologic and renal data, as well as electrolytes obtained before and 24 h after treatment. For radiation dosimetry, whole-body scans were performed at 1, 24, and 48 h and a SPECT/CT scan was performed at 48 h, along with blood sampling at 5 min and 0.5, 2, 4, 24, and 48 h after administration. Absorbed dose estimations for the kidneys and bone marrow were performed according to the MIRD concept. Results: In 15 treatment cycles, PAH was coinfused. No changes in mean creatinine level, glomerular filtration rate, and serum electrolytes were observed before or 24 h after treatment when using PAH protection (P ≥ 0.20), whereas serum chloride and serum phosphate increased significantly under AA (both P < 0.01). Kidney-absorbed dose coefficients were 0.60 ± 0.14 Gy/GBq with PAH and 0.53 ± 0.16 Gy/GBq with AA. Based on extrapolated cumulative kidney-absorbed doses for 4 cycles, 1 patient with PAH protection and 1 patient with AA protection in our patient group would exceed the 23-Gy conservative threshold. The bone marrow-absorbed dose coefficient was 0.012 ± 0.004 Gy/GBq with PAH and 0.012 ± 0.003 Gy/GBq with AA. Conclusion: PAH is a promising alternative to AA for renal protection during peptide receptor radiotherapy. Further research is required to systematically investigate the safety profile and radiation dosimetry at varying PAH plasma concentrations.

5.
EJNMMI Phys ; 11(1): 3, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38167953

RESUMO

AIM: Positron emission tomography (PET) using 124I-mIBG has been established for imaging and pretherapeutic dosimetry. Here, we report the first systematic analysis of the biodistribution and radiation dosimetry of 124I-mIBG in patients with neural crest tumours and project the results to paediatric patient models. METHODS: Adult patients with neural crest tumours who underwent sequential 124I-mIBG PET were included in this retrospective single-center analysis. PET data were acquired 4, 24, 48, and/or 120 h after administration of a mean of 43 MBq 124I-mIBG. Whole-body counting and blood sampling were performed at 2, 4, 24, 48 and 120 h after administration. Absorbed organ dose and effective dose coefficients were estimated in OLINDA/EXM 2.2 according to the MIRD formalism. Extrapolation to paediatric models was performed based on mass-fraction scaling of the organ-specific residence times. Biodistribution data for adults were also projected to 123I-mIBG and 131I-mIBG. RESULTS: Twenty-one patients (11 females, 10 males) were evaluated. For adults, the organs exposed to the highest dose per unit administered activity were urinary bladder (1.54 ± 0.40 mGy/MBq), salivary glands (0.77 ± 0.28 mGy/MBq) and liver (0.65 ± 0.22 mGy/MBq). Mean effective dose coefficient for adults was 0.25 ± 0.04 mSv/MBq (male: 0.24 ± 0.03 mSv/MBq, female: 0.26 ± 0.06 mSv/MBq), and increased gradually to 0.29, 0.44, 0.69, 1.21, and 2.94 mSv/MBq for the 15-, 10-, 5-, 1-years-old, and newborn paediatric reference patients. Projected mean effective dose coefficients for 123I-mIBG and 131I-mIBG for adults were 0.014 ± 0.002 mSv/MBq and 0.18 ± 0.04 mSv/MBq, respectively. CONCLUSION: PET-based derived radiation dosimetry data for 124I-mIBG from this study agreed well with historical projected data from ICRP 53. The effective dose coefficients presented here may aid in guidance for establishing weight-based activity administration protocols.

6.
J Nucl Med ; 64(Suppl 2): 29S-38S, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37918843

RESUMO

Novel therapeutic options have significantly improved survival and long-term outcomes in many cancer entities. Unfortunately, this improvement in outcome is often accompanied by new and increasingly relevant therapy-related cardiovascular toxicity. In this context, cardiooncology has emerged as a new field of interdisciplinary individual patient care. Important tasks are pretherapeutic risk stratification and early detection and treatment of cardiotoxicity, which comprises cardiac damage in relation to cardiovascular comorbidities, the tumor disease, and cancer treatment. Clinical manifestations can cover a broad spectrum, ranging from subtle and usually asymptomatic abnormalities to serious acute or chronic complications. Typical manifestations include acute and chronic heart failure, myo- and pericarditis, arrythmias, ischemia, and endothelial damage. They can be related to almost all current cancer treatments, including cytotoxic chemotherapy, targeted therapy, immunotherapy, hormonal therapy, and radiotherapy. Molecular imaging biomarkers can aid in pretherapeutic cardiooncologic assessment for primary prevention and personalized surveillance, detection, and differential diagnosis of cardiotoxic complications. Potential advantages over conventional diagnostics are the higher detection sensitivity for subtle changes in cardiac homeostasis, higher reproducibility, and better observer independence. Hybrid imaging with highly sensitive PET/MRI may be particularly suited for early diagnosis. Important technologies that are encouraged in current multidisciplinary guidelines are equilibrium radionuclide angiography for evaluation of ventricular function and chamber morphology, as well as myocardial perfusion imaging for additional detection of ischemia. Novel modalities that may detect even earlier signs of cardiotoxicity comprise 123I-metaiodobenzylguanidine SPECT to visualize sympathetic innervation, 18F-FDG and somatostatin receptor (68Ga-DOTATOC/DOTATATE) PET to indicate a metabolic shift and inflammation, and 68Ga-fibroblast activation protein inhibitor PET to monitor cardiac remodeling. In addition, PET imaging of mitochondrial function has recently been introduced in preclinical models and will potentially broaden the field of application through higher sensitivity and specificity and by enabling higher individualization of diagnostic concepts.


Assuntos
Cardiotoxicidade , Neoplasias , Humanos , Radioisótopos de Gálio/uso terapêutico , Reprodutibilidade dos Testes , Detecção Precoce de Câncer , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Biomarcadores , Imagem Molecular , Isquemia/complicações
7.
Phys Med ; 114: 103149, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37778973

RESUMO

PURPOSE: The aim of this study was to investigate conditions for reliable quantification of sub-centimeter lesions with low18F,68Ga, and124I uptake using a silicon photomultiplier-based PET/CT system. METHODS: A small tumor phantom was investigated under challenging but clinically realistic conditions resembling prostate and thyroid cancer lymph node metastases (6 spheres with 3.7-9.7 mm in diameter, 9 different activity concentrations ranging from about 0.25-25 kBq/mL, and a signal-to-background ratio of 20). Radionuclides with different positron branching ratios and prompt gamma coincidence contributions were investigated. Maximum-, contour-, and oversize-based partial volume effect (PVE) correction approaches were applied. Detection and quantification performance were estimated, considering a ±30 % deviation between imaged-derived and true activity concentrations as acceptable. A standard and a prolonged acquisition time and two image reconstruction algorithms (time-of-flight with/without point spread function modelling) were analyzed. Clinical data were evaluated to assess agreement of PVE-correction approaches indicating lesion quantification validity. RESULTS: The smallest 3.7-mm sphere was not visible. If the lesions were clearly observed, quantification was, except for a few cases, acceptable using contour- or oversized-based PVE-corrections. Quantification accuracy did not substantially differ between 18F, 68Ga, and 124I. No systematic differences between the analyzed reconstruction algorithms or shorter and larger acquisition times were observed. In the clinical evaluation of 20 lesions, an excellent statistical agreement between oversize- and contour-based PVE-corrections was observed. CONCLUSIONS: At the lower end of size (<10 mm) and activity concentration ranges of lymph-node metastases, quantification with reasonable accuracy is possible for 18F, 68Ga, and 124I, possibly allowing pre-therapeutic lesion dosimetry and individualized radionuclide therapy planning.


Assuntos
Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos do Iodo/uso terapêutico , Radiometria , Tomografia por Emissão de Pósitrons
8.
Cancers (Basel) ; 15(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37509242

RESUMO

Historically, molecular imaging of somatostatin receptor (SSTR) expression in patients with neuroendocrine tumors (NET) was performed using SSTR scintigraphy (SRS). Sustained advances in medical imaging have led to its gradual replacement with SSTR positron-emission tomography (SSTR-PET). The higher sensitivity in comparison to SRS on the one hand and conventional cross-sectional imaging, on the other hand, enables more accurate staging and allows for image quantification. In addition, in recent years, a growing body of evidence has assessed the prognostic implications of SSTR-PET-derived prognostic biomarkers for NET patients, with the aim of risk stratification, outcome prognostication, and prediction of response to peptide receptor radionuclide therapy. In this narrative review, we give an overview of studies examining the prognostic value of advanced SSTR-PET-derived (semi-)quantitative metrics like tumor volume, uptake, and composite metrics. Complementing this analysis, a discussion of the current trends, clinical implications, and future directions is provided.

9.
J Nucl Med ; 64(10): 1540-1549, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37474272

RESUMO

PET imaging using the somatostatin receptor 2 (SSTR2) antagonist satoreotide trizoxetan (SSO-120, previously OPS-202) could offer accurate tumor detection and screening for SSTR2-antagonist radionuclide therapy in patients with SSTR2-expressing small cell lung cancer (SCLC). The aim of this single-center study was to investigate tumor uptake and detection rates of 68Ga-SSO-120 in comparison to 18F-FDG PET in the initial staging of SCLC patients. Methods: Patients with newly diagnosed SCLC who underwent additional whole-body 68Ga-SSO-120 PET/CT during the initial diagnostic workup were retrospectively included. The mean administered activity was 139 MBq, and the mean uptake time was 60 min. Gold-standard staging 18F-FDG PET/CT was evaluated if available within 2 wk before or after 68Ga-SSO-120 PET if morphologic differences in CT images were absent. 68Ga-SSO-120- or 18F-FDG-positive lesions were reported in 7 anatomic regions (primary tumor, thoracic lymph node metastases, and distant metastases including pleural, contralateral pulmonary, liver, bone, and other) according to the TNM classification for lung cancer (eighth edition). Consensus TNM staging (derived from CT, endobronchial ultrasound-guided transbronchial needle aspiration, PET, and brain MRI) by a clinical tumor board served as the reference standard. Results: Thirty-one patients were included, 12 with limited and 19 with extensive disease according to the Veterans Administration Lung Study Group classification. 68Ga-SSO-120-positive tumor was detected in all patients (100%) and in 90 of the 217 evaluated regions (41.5%). Thirteen patients (42.0%) had intense average 68Ga-SSO-120 uptake (region-based mean SUVmax ≥ 10); 28 patients (90.3%) had average 68Ga-SSO-120 uptake greater than liver uptake (region-based mean peak tumor-to-liver ratio > 1). In 25 patients with evaluable 18F-FDG PET, primary tumor, thoracic lymph node metastases, and distant metastases were detected in 100%, 92%, and 64%, respectively, of all investigated patients by 68Ga-SSO-120 and in 100%, 92%, and 56%, respectively, by 18F-FDG PET. 68Ga-SSO-120 PET detected additional contralateral lymph node, liver, and brain metastases in 1, 1, and 2 patients, respectively (no histopathology available), and 18F-FDG PET detected additional contralateral lymph node metastases in 3 patients (1 confirmed, 1 systematic endobronchial ultrasound-guided transbronchial needle aspiration-negative, and 1 without available histopathology). None of these differences altered Veterans Administration Lung Study Group staging. The region-based monotonic correlation between 68Ga-SSO-120 and 18F-FDG uptake was low (Spearman ρ = 0.26-0.33). Conclusion: 68Ga-SSO-120 PET offers high diagnostic precision with comparable detection rates and additional complementary information to the gold standard, 18F-FDG PET. Consistent uptake in most patients warrants exploration of SSTR2-directed radionuclide therapy.


Assuntos
Neoplasias Pulmonares , Carcinoma de Pequenas Células do Pulmão , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Carcinoma de Pequenas Células do Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Metástase Linfática , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias
10.
J Nucl Med ; 64(7): 1083-1086, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37290801

RESUMO

Cardiac transthyretin amyloidosis is an infiltrative cardiomyopathy with high mortality. To date, there are no specific biomarkers to directly assess disease activity and response to specific treatments. Our aim was to evaluate scintigraphic changes after treatment with the transthyretin stabilizer tafamidis. Methods: We included patients who had undergone 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (99mTc-DPD) scintigraphy before tafamidis initiation and after at least 9 mo. Tracer activity was assessed visually and quantitatively as SUVmax Results: The study included 14 patients who were on tafamidis for 44 ± 14 mo. We observed regression of Perugini grade in 5 patients, unchanged grade in 9 patients, and regression of mean heart-to-contralateral-lung ratio (P = 0.015) and SUVmax (P = 0.005). There were no changes in N-terminal pro-B-type natriuretic peptide or echocardiographic measures. Conclusion: Treatment with tafamidis results in regression of myocardial 99mTc-DPD uptake. 99mTc-DPD scintigraphy may provide useful imaging biomarkers to assess response to treatment.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Humanos , Pré-Albumina , Compostos de Organotecnécio , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/tratamento farmacológico
11.
Semin Nucl Med ; 53(5): 687-693, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37037684

RESUMO

This review provides an overview of the current opportunities for integrating artificial intelligence methods into the field of preclinical imaging research in nuclear medicine. The growing demand for imaging agents and therapeutics that are adapted to specific tumor phenotypes can be excellently served by the evolving multiple capabilities of molecular imaging and theranostics. However, the increasing demand for rapid development of novel, specific radioligands with minimal side effects that excel in diagnostic imaging and achieve significant therapeutic effects requires a challenging preclinical pipeline: from target identification through chemical, physical, and biological development to the conduct of clinical trials, coupled with dosimetry and various pre, interim, and post-treatment staging images to create a translational feedback loop for evaluating the efficacy of diagnostic or therapeutic ligands. In virtually all areas of this pipeline, the use of artificial intelligence and in particular deep-learning systems such as neural networks could not only address the above-mentioned challenges, but also provide insights that would not have been possible without their use. In the future, we expect that not only the clinical aspects of nuclear medicine will be supported by artificial intelligence, but that there will also be a general shift toward artificial intelligence-assisted in silico research that will address the increasingly complex nature of identifying targets for cancer patients and developing radioligands.


Assuntos
Neoplasias , Medicina Nuclear , Humanos , Inteligência Artificial , Redes Neurais de Computação , Imagem Molecular , Neoplasias/diagnóstico por imagem
12.
Eur J Nucl Med Mol Imaging ; 50(7): 2196-2209, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36859618

RESUMO

PURPOSE: The aim of this study was to systematically evaluate the effect of thresholding algorithms used in computer vision for the quantification of prostate-specific membrane antigen positron emission tomography (PET) derived tumor volume (PSMA-TV) in patients with advanced prostate cancer. The results were validated with respect to the prognostication of overall survival in patients with advanced-stage prostate cancer. MATERIALS AND METHODS: A total of 78 patients who underwent [177Lu]Lu-PSMA-617 radionuclide therapy from January 2018 to December 2020 were retrospectively included in this study. [68Ga]Ga-PSMA-11 PET images, acquired prior to radionuclide therapy, were used for the analysis of thresholding algorithms. All PET images were first analyzed semi-automatically using a pre-evaluated, proprietary software solution as the baseline method. Subsequently, five histogram-based thresholding methods and two local adaptive thresholding methods that are well established in computer vision were applied to quantify molecular tumor volume. The resulting whole-body molecular tumor volumes were validated with respect to the prognostication of overall patient survival as well as their statistical correlation to the baseline methods and their performance on standardized phantom scans. RESULTS: The whole-body PSMA-TVs, quantified using different thresholding methods, demonstrate a high positive correlation with the baseline methods. We observed the highest correlation with generalized histogram thresholding (GHT) (Pearson r (r), p value (p): r = 0.977, p < 0.001) and Sauvola thresholding (r = 0.974, p < 0.001) and the lowest correlation with Multiotsu (r = 0.877, p < 0.001) and Yen thresholding methods (r = 0.878, p < 0.001). The median survival time of all patients was 9.87 months (95% CI [9.3 to 10.13]). Stratification by median whole-body PSMA-TV resulted in a median survival time from 11.8 to 13.5 months for the patient group with lower tumor burden and 6.5 to 6.6 months for the patient group with higher tumor burden. The patient group with lower tumor burden had significantly higher probability of survival (p < 0.00625) in eight out of nine thresholding methods (Fig. 2); those methods were SUVmax50 (p = 0.0038), SUV ≥3 (p = 0.0034), Multiotsu (p = 0.0015), Yen (p = 0.0015), Niblack (p = 0.001), Sauvola (p = 0.0001), Otsu (p = 0.0053), and Li thresholding (p = 0.0053). CONCLUSION: Thresholding methods commonly used in computer vision are promising tools for the semiautomatic quantification of whole-body PSMA-TV in [68Ga]Ga-PSMA-11-PET. The proposed algorithm-driven thresholding strategy is less arbitrary and less prone to biases than thresholding with predefined values, potentially improving the application of whole-body PSMA-TV as an imaging biomarker.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Humanos , Masculino , Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Neoplasias de Próstata Resistentes à Castração/patologia , Estudos Retrospectivos , Carga Tumoral
13.
Q J Nucl Med Mol Imaging ; 67(1): 57-68, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34309334

RESUMO

BACKGROUND: The aim of this phantom study was to optimize the [68Ga]Ga-PSMA PET/CT examination in terms of scan time duration and image reconstruction parameters, in combination with PSF and TOF modelling, in a digital Biograph Vision PET/CT scanner. METHODS: Three types of phantoms were used: 1) soft-tissue tumor phantom consisting of six spheres mounted in a torso phantom; 2) bone-lung tumor phantom; 3) resolution phantom. Phantom inserts were filled with activity concentrations (ACs) that were derived from clinical data. Phantom data were acquired in list-mode at one bed position. Images with emission data ranging from 30 to 210 s in 30-s increments were reconstructed from a reference image acquired with 3.5-min emission. Iterative image reconstruction (OSEM), point-spread-function (PSF) and time-of-flight (TOF) options were applied using different iterations, Gaussian filters, and voxel sizes. The criteria for image quality was lesion detectability and lesion quantification, evaluated as contrast-to-noise ratio (CNR) and maximum AC (peak AC), respectively. A threshold value of CNR above 6 and percentage maximum AC (peak AC) deviation range of ±20% of the reference image were considered acceptable. The proposed single-bed scan time reduction was projected to a whole-body examination (patient validation scan) using the continuous-bed-motion mode. RESULTS: Sphere and background ACs of 20 kBq/mL and 1 kBq/mL were selected, respectively. The optimized single-bed scan time was approximately 60 s using OSEM-TOF or OSEM-TOF+PSF (four iterations, 4.0-mm Gaussian filter and almost isotropic voxel size of 3.0-mm side length), resulting in a PET spatial resolution of 6.3 mm for OSEM-TOF and 5.5 mm for OSEM-TOF+PSF. In the patient validation, the maximum percentage difference in lesion quantification between standard and optimized protocol (whole-body scan time of 15 vs. 5 min) was below 19%. CONCLUSIONS: A reduction of single-bed and whole-body scan time for [68Ga]Ga-PSMA PET/CT compared to current recommended clinical acquisition protocols is postulated. Clinical studies are warranted to validate the applicability of this protocol.


Assuntos
Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Fatores de Tempo , Imagens de Fantasmas
14.
J Nucl Cardiol ; 30(1): 101-111, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35562639

RESUMO

INTRODUCTION: Transthyretin (ATTR) amyloidosis is responsible for the majority of cardiac amyloidosis (CA) cases and can be reliably diagnosed with bone scintigraphy and the visual Perugini score. We aimed to implement a quantification method of cardiac amyloid deposits in patients with suspected cardiac amyloidosis and to compare performance to visual scoring. METHODS AND MATERIALS: 136 patients received 99mTc-DPD-bone scintigraphy including SPECT/CT of the thorax in case of suspicion of cardiac amyloidosis. Imaging phantom studies were performed to determine the scaling factor for standardized uptake value (SUV) quantification from SPECT/CT. Myocardial tracer uptake was quantified in a whole heart volume of interest. RESULTS: Forty-five patients were diagnosed with CA. A strong relationship between cardiac SUVmax and Perugini score was found (Spearman r 0.75, p < 0.0001). Additionally, tracer uptake in bone decreased with increasing cardiac SUVmax and Perugini score (p < 0.0001). ROC analysis revealed good performance of the SUVmax for the detection of ATTR-CA with AUC of 0.96 ± 0.02 (p < 0.0001) with sensitivity 98.7% and specificity 87.2%. CONCLUSION: We demonstrate an accessible and accurate quantitative SPECT approach in CA. Quantitative assessment of the cardiac tracer uptake may improve diagnostic accuracy and risk classification. This method may enable monitoring and assessment of therapy response in patients with ATTR amyloidosis.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Coração , Pré-Albumina , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
15.
J Nucl Med ; 64(2): 329-336, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35981898

RESUMO

Therapy with 90Y-labeled fibroblast activation protein inhibitors (90Y-FAPIs) was recently introduced as a novel treatment concept for patients with solid tumors. Lesion and organ-at-risk dosimetry is part of assessing treatment efficacy and safety and requires reliable quantification of tissue uptake. As 90Y quantification is limited by the low internal positron-electron pair conversion rate, the increased effective sensitivity of digital silicon photomultiplier-based PET/CT systems might increase quantification accuracy and, consequently, allow for dosimetry in 90Y-FAPI therapy. The aim of this study was to explore the conditions for reliable lesion image quantification in 90Y-FAPI radionuclide therapy using a digital PET/CT system. Methods: Two tumor phantoms were filled with 90Y solution using different sphere activity concentrations and a constant signal-to-background ratio of 40. The minimum detectable activity concentration was determined, and its dependence on acquisition time (15 vs. 30 min per bed position) and smoothing levels (all-pass vs. 5-mm gaussian filter) was investigated. Quantification accuracy was evaluated at various activity concentrations to estimate the minimum quantifiable activity concentration using contour-based and oversized volume-of-interest-based quantification approaches. A ±20% deviation range between image-derived and true activity concentrations was regarded as acceptable. Tumor dosimetry for 3 patients treated with 90Y-FAPI is presented to project the phantom results to clinical scenarios. Results: For a lesion size of 40 mm and a clinical acquisition time of 15 min, both minimum detectable and minimum quantifiable activity concentrations were 0.12 MBq/mL. For lesion sizes of greater than or equal to 30 mm, accurate quantification was feasible for detectable lesions. Only for the smallest 10-mm sphere, the minimum detectable and minimum quantifiable activity concentrations differ substantially (0.43 vs. 1.97 MBq/mL). No notable differences between the 2 quantification approaches were observed. For the investigated tumors, absorbed dose estimates with reliable accuracy were achievable. Conclusion: For lesion sizes and activity concentrations that are expected to be observed in patients treated with 90Y-FAPI, quantification with reasonable accuracy is possible. Further dosimetry studies are needed to thoroughly investigate the efficacy and safety of 90Y-FAPI therapy.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Radioisótopos de Ítrio/uso terapêutico , Tomografia por Emissão de Pósitrons/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Neoplasias/tratamento farmacológico , Fibroblastos , Radioisótopos de Gálio
16.
J Nucl Med ; 64(3): 372-378, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36137757

RESUMO

We analyzed the diagnostic performance of prostate-specific membrane antigen (PSMA) PET/CT and the dosimetry, efficacy, and safety of 177Lu-PSMA-617 radioligand therapy (RLT) in salivary gland malignancies (SGMs). Methods: We identified 28 SGM patients with PSMA PET/CT from our database. CT and PSMA PET/CT images were evaluated separately by 3 masked readers in joint reading sessions. Pathologic findings were grouped into 6 TNM regions, and lesion-based disease extent was classified as no disease (n = 1, 4%), unifocal (n = 2, 7%), oligometastatic (n = 9, 32%), multifocal (n = 3, 11%), or disseminated (n = 13, 47%). For each region, the SUVmax of the lesion with the highest uptake was measured and the visual PSMA expression score was evaluated on a per-patient basis using PROMISE criteria. The association between PSMA expression and clinical and histopathologic markers was tested using the Student t test. Five patients underwent PSMA RLT with intratherapeutic dosimetry. Response was assessed using RECIST 1.1, and adverse events were graded according to version 5.0 of the Common Terminology Criteria for Adverse Events. Results: Compared with CT, PSMA PET/CT demonstrated additional metastatic lesions in 11 of 28 (39%) patients, leading to upstaging of TNM and lesion-based disease extent in 3 (11%) and 6 (21%) patients, respectively. PSMA PET/CT detected CT-occult local tumor, regional lymph nodes, nonregional lymph nodes, and bone metastases in 1 (4%), 4 (14%), 2 (7%), and 4 (14%) patients, respectively; no additional lesions were detected in the other predefined regions. PSMA expression level was higher than liver in 6 patients (25%). A significantly higher SUVmax was observed in male than female patients (15.8 vs. 8.5, P = 0.007) and in bone than lung lesions (14.2 vs. 6.4, P = 0.006). PSMA RLT was discontinued after 1 cycle in 3 of 5 patients because of insufficient tumor doses. No adverse events of grade 4 or higher occurred. Conclusion: In SGMs, PSMA PET/CT demonstrated a superior detection rate and led to upstaging in about one third of patients when compared with CT. The male sex and the presence of bone metastases were associated with significantly higher PSMA expression. PSMA RLT was well tolerated, but most patients did not have more than 1 cycle because of insufficient tumor doses.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias das Glândulas Salivares , Humanos , Masculino , Feminino , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Gálio , Dipeptídeos/uso terapêutico , Antígeno Prostático Específico , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Neoplasias das Glândulas Salivares/radioterapia
17.
J Nucl Med ; 64(4): 598-604, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36357181

RESUMO

Intraoperative identification of positive resection margins (PRMs) in high-risk prostate cancer (PC) needs improvement. Cerenkov luminescence imaging (CLI) with 68Ga-PSMA-11 is promising, although limited by low residual activity and artificial signals. Here, we aimed to assess the value of CLI and flexible autoradiography (FAR) with 18F-PSMA-1007. Methods: Mice bearing subcutaneous PSMA-avid RM1-PGLS tumors were administered 18F-PSMA-1007, and PET/CT was performed. After the animals had been killed, organs were excised and measured signals in CLI and FAR CLI were correlated with tracer activity concentrations (ACs) obtained from PET/CT. For clinical assessment, 7 high-risk PC patients underwent radical prostatectomy immediately after preoperative 18F-PSMA PET/CT. Contrast-to-noise ratios (CNRs) were calculated for both imaging modalities in intact specimens and after incision above the index lesion. Results: In the heterotopic in vivo mouse model (n = 5), CLI did not detect any lesion. FAR CLI detected a distinct signal in all mice, with a lowest AC of 7.25 kBq/mL (CNR, 5.48). After incision above the index lesion of the prostate specimen, no increased signal was observed at the cancer area in CLI. In contrast, using FAR CLI, a signal was detectable in 6 of 7 patients. The AC in the missed index lesion was 1.85 kBq/mL, resulting in a detection limit of at least 2.06 kBq/mL. Histopathology demonstrated 2 PRMs, neither of which was predicted by CLI or FAR CLI. Conclusion: 18F-PSMA FAR CLI was superior to CLI in tracer-related signal detectability. PC was could be visualized in radical prostatectomy down to 2.06 kBq/mL. However, the detection of PRMs was limited. Direct anatomic correlation of FAR CLI is challenging because of the scintillator overlay.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Masculino , Animais , Camundongos , Próstata/diagnóstico por imagem , Próstata/cirurgia , Próstata/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Autorradiografia , Luminescência , Estudos de Viabilidade , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Radioisótopos de Gálio , Prostatectomia/métodos
18.
Leukemia ; 36(12): 2845-2852, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36241697

RESUMO

The randomized PETAL trial failed to demonstrate a benefit of interim FDG-PET (iPET)-based treatment intensification over continued standard therapy with CHOP (plus rituximab (R) in CD20-positive lymphomas). We hypothesized that PET analysis of all lymphoma manifestations may identify patients who benefitted from treatment intensification. A previously developed neural network was employed for iPET analysis to identify the highest pathological FDG uptake (max-SUVAI) and the mean FDG uptake of all lymphoma manifestations (mean-SUVAI). High mean-SUVAI uptake was determined separately for iPET-positive and iPET-negative patients. The endpoint was time-to-progression (TTP). There was a significant interaction of additional rituximab and mean-SUVAI in the iPET-negative group (HR = 0.6, p < 0.05). Patients with high mean-SUVAI had significantly prolonged TTP when treated with 6xR-CHOP + 2 R (not reached versus 52 months, p < 0.05), whereas max-SUVmanual failed to show an impact of additional rituximab. In the iPET-positive group, patients with high mean-SUVAI had a significantly longer TTP with (R-)CHOP than with the Burkitt protocol (14 versus 4 months, p < 0.01). Comprehensive iPET evaluation may provide new prognosticators in aggressive lymphoma. Additional application of rituximab was associated with prolonged TTP in iPET-negative patients with high mean-SUVAI. Comprehensive iPET interpretation could identify high-risk patients who benefit from study-specific interventions.


Assuntos
Fluordesoxiglucose F18 , Linfoma não Hodgkin , Humanos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Ciclofosfamida/uso terapêutico , Doxorrubicina/uso terapêutico , Linfoma não Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/tratamento farmacológico , Tomografia por Emissão de Pósitrons/métodos , Prednisona/uso terapêutico , Rituximab , Vincristina/uso terapêutico
19.
BMC Cancer ; 22(1): 899, 2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-35978274

RESUMO

BACKGROUND: New-generation silicon-photomultiplier (SiPM)-based PET/CT systems exhibit an improved lesion detectability and image quality due to a higher detector sensitivity. Consequently, the acquisition time can be reduced while maintaining diagnostic quality. The aim of this study was to determine the lowest 18F-FDG PET acquisition time without loss of diagnostic information and to optimise image reconstruction parameters (image reconstruction algorithm, number of iterations, voxel size, Gaussian filter) by phantom imaging. Moreover, patient data are evaluated to confirm the phantom results. METHODS: Three phantoms were used: a soft-tissue tumour phantom, a bone-lung tumour phantom, and a resolution phantom. Phantom conditions (lesion sizes from 6.5 mm to 28.8 mm in diameter, lesion activity concentration of 15 kBq/mL, and signal-to-background ratio of 5:1) were derived from patient data. PET data were acquired on an SiPM-based Biograph Vision PET/CT system for 10 min in list-mode format and resampled into time frames from 30 to 300 s in 30-s increments to simulate different acquisition times. Different image reconstructions with varying iterations, voxel sizes, and Gaussian filters were probed. Contrast-to-noise-ratio (CNR), maximum, and peak signal were evaluated using the 10-min acquisition time image as reference. A threshold CNR value ≥ 5 and a maximum (peak) deviation of ± 20% were considered acceptable. 20 patient data sets were evaluated regarding lesion quantification as well as agreement and correlation between reduced and full acquisition time standard uptake values (assessed by Pearson correlation coefficient, intraclass correlation coefficient, Bland-Altman analyses, and Krippendorff's alpha). RESULTS: An acquisition time of 60 s per bed position yielded acceptable detectability and quantification results for clinically relevant phantom lesions ≥ 9.7 mm in diameter using OSEM-TOF or OSEM-TOF+PSF image reconstruction, a 4-mm Gaussian filter, and a 1.65 × 1.65 x 2.00-mm3 or 3.30 × 3.30 x 3.00-mm3 voxel size. Correlation and agreement of patient lesion quantification between full and reduced acquisition times were excellent. CONCLUSION: A threefold reduction in acquisition time is possible. Patients might benefit from more comfortable examinations or reduced radiation exposure, if instead of the acquisition time the applied activity is reduced.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons
20.
Eur J Nucl Med Mol Imaging ; 49(13): 4503-4515, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35904589

RESUMO

PURPOSE: Both digital positron emission tomography (PET) detector technologies and artificial intelligence based image post-reconstruction methods allow to reduce the PET acquisition time while maintaining diagnostic quality. The aim of this study was to acquire ultra-low-count fluorodeoxyglucose (FDG) ExtremePET images on a digital PET/computed tomography (CT) scanner at an acquisition time comparable to a CT scan and to generate synthetic full-dose PET images using an artificial neural network. METHODS: This is a prospective, single-arm, single-center phase I/II imaging study. A total of 587 patients were included. For each patient, a standard and an ultra-low-count FDG PET/CT scan (whole-body acquisition time about 30 s) were acquired. A modified pix2pixHD deep-learning network was trained employing 387 data sets as training and 200 as test cohort. Three models (PET-only and PET/CT with or without group convolution) were compared. Detectability and quantification were evaluated. RESULTS: The PET/CT input model with group convolution performed best regarding lesion signal recovery and was selected for detailed evaluation. Synthetic PET images were of high visual image quality; mean absolute lesion SUVmax (maximum standardized uptake value) difference was 1.5. Patient-based sensitivity and specificity for lesion detection were 79% and 100%, respectively. Not-detected lesions were of lower tracer uptake and lesion volume. In a matched-pair comparison, patient-based (lesion-based) detection rate was 89% (78%) for PERCIST (PET response criteria in solid tumors)-measurable and 36% (22%) for non PERCIST-measurable lesions. CONCLUSION: Lesion detectability and lesion quantification were promising in the context of extremely fast acquisition times. Possible application scenarios might include re-staging of late-stage cancer patients, in whom assessment of total tumor burden can be of higher relevance than detailed evaluation of small and low-uptake lesions.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Prospectivos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA